Plan my home
LOCATION: GURGAON, HR
TYPE: PENTHOUSE
AREA: 8,500 SQ. FT.
YEAR: 2026

The Camellias Residence

The owners wanted technology that disappeared into the background. That meant selecting a wired backbone where reliability mattered most, while introducing wireless devices only where they genuinely improved flexibility.

Living area architectural lighting designed to transition naturally from daytime to evening

FIG. 1.1 — LIVING AREA ARCHITECTURAL LIGHTING TRANSITIONING NATURALLY FROM DAYTIME TO EVENING.

DESIGN PHILOSOPHY

Removing Everyday Friction

The brief was not to automate everything.

It was to remove everyday friction.

Lighting follows the time of day naturally. Climate responds to room occupancy. Technology stays quietly in the background without demanding attention.

"The best technology is the technology you stop noticing."
ARCHITECTURAL PRINCIPLE · THE SKYLINE RESIDENCE
CONTEXT & CONSTRAINTS

The Client Brief

The client is a family moving into a two-story penthouse. They required a home that felt serene for guests while remaining straightforward for children and house staff to operate.

Coastal humidity and voltage spikes required isolating electronic controllers inside sealed distribution cabinets. In addition, 22-foot west-facing glass windows created intense afternoon solar heat gain, requiring shade automation linked directly to the sun's position.

Wall space had to remain completely free from plastic gang boxes, preserving fair-faced concrete and custom timber joinery.

Flush-mounted brass keypads integrated into custom timber paneling

FIG. 2.1 — FLUSH-MOUNTED BRASS KEYPADS INTEGRATED INTO TIMBER JOINERY.

Kitchen prep lighting and integrated climate sensors

FIG. 2.2 — KITCHEN PREP LIGHTING AND INTEGRATED CLIMATE SENSORS.

DESIGN DECISIONS

Engineering Rationale

LIGHTING CONTROL

We selected DALI-2 digital addressable dimming.

Why: DALI-2 sends digital dimming instructions directly to individual LED drivers over two wires. This allowed smooth dimming down to 0.1% intensity without strobe flicker, while reporting driver health telemetry to the central panel.

AUTOMATION BACKBONE

We selected a wired KNX twisted-pair bus.

Why: KNX (ISO/IEC 14543) has no central server failure point. Every keypad and relay contains onboard microprocessors. If a single module fails, every other lighting loop, shade motor, and sensor operates normally.

HVAC INTEGRATION

We selected direct RS-485 VRV bus gateways.

Why: Standard wall thermostats force simple ON/OFF cycles that strain VRF compressors. Interfacing directly with the Daikin internal bus allowed fan speed modulation and return-air temperature telemetry.

NETWORKING

We selected enterprise switches with dedicated VLANs.

Why: Separating automation traffic from guest Wi-Fi prevents latency and eliminates security risks. Flush ceiling-mounted access points provide uninterrupted Wi-Fi roaming across both floors.

SIGNATURE DIAGNOSTIC

Why This Home Works

A step-by-step alignment between architecture, lifestyle, and engineering choices.

01 ARCHITECTURE Timber & Concrete
02 LIFESTYLE Family & Staff
03 ENGINEERING Concealed Wiring
04 TECHNOLOGY KNX & DALI-2
05 OUTCOME Calm Living
ROOM EXPERIENCE

Living Inside The Space

Living Room

When afternoon sunlight hits the western glass facade, motorized shades lower automatically to block heat while preserving city views. Indirect cove lighting brightens as dusk arrives, maintaining a warm atmosphere.

Kitchen & Dining

Task lighting over prep islands provides clear illumination during meal preparation. Selecting "Dining Scene" softens island pendants to a warm dim level while starting background music at gentle conversational volumes.

Master Bedroom Suite

Tapping "Goodnight" lowers blackout drapes, sets the AC to night setback temperature, and confirms exterior door locks. Low-level footwell lights illuminate paths automatically for night visits.

PROJECT OUTCOMES

What Improved

FREQUENTLY ASKED QUESTIONS

Practical Clarifications

Why was this approach chosen? expand_more

Because the owners requested a home that felt calm and intuitive. Planning low-voltage conduits before civil construction allowed keypads to be integrated into timber joinery rather than added as visible surface boxes.

What happens if the internet connection fails? expand_more

The home continues to function normally. Lighting scenes, keypads, climate schedules, and motorized blinds operate over local bus wires without relying on internet servers.

RELATED CASE STUDIES

Projects With Similar Constraints

Apartment · Wireless Mesh

Control Hub Residence

Retrofit in a high-rise penthouse resolving concrete shear wall limitations without wall cutting.

View Case Study →
Penthouse · Wired Bus

The Camellias Residence

Low-voltage engineering featuring concealed keypads and double-height curtain tracking.

View Case Study →
INITIAL CONSULTATION

Planning a home?

Let's discuss the way you want to live before we discuss technology.